Product details
2020 Candela GentleMax Pro
Dual Wavelength Laser System for Versatile Aesthetic Treatments
Introduction to the 2020 Candela GentleMax Pro
The 2020 Candela GentleMax Pro is a high performance dual wavelength laser platform designed to support a wide range of aesthetic treatments. Moreover, this system combines advanced laser engineering with reliable clinical performance. As a result, it delivers consistent outcomes across diverse skin types and indications.
Dual Wavelength Technology Explained
A dual wavelength laser system provides greater treatment flexibility. Therefore, practitioners can customize treatments based on patient needs. In addition, multiple wavelengths allow safer energy delivery across different skin tones.
Alexandrite Wavelength for Precision Treatments
The Alexandrite wavelength is highly absorbed by melanin. Consequently, it delivers effective energy to targeted structures. Furthermore, this makes it suitable for precise hair removal and pigment focused treatments.
Nd YAG Wavelength for Deeper Penetration
Nd YAG penetrates deeper into the skin with lower melanin absorption. As a result, it is safer for darker skin types. Moreover, it supports vascular and deeper follicular treatments.
Core Technology Behind GentleMax Pro
High Performance Laser Platform
The system is engineered for stable and consistent energy output. Therefore, treatment results remain predictable. In addition, advanced pulse control improves procedural safety.
Integrated Cooling System
An integrated cooling mechanism protects the epidermis during treatment. As a result, patient comfort is enhanced. Furthermore, cooling allows higher treatment efficiency.
Flexible Spot Size Options
The GentleMax Pro supports multiple spot sizes. Consequently, it accommodates both small and large treatment areas. Moreover, this flexibility improves workflow efficiency.
Key Features of 2020 Candela GentleMax Pro
Intelligent Control Interface
A user friendly interface simplifies treatment setup. Therefore, operators can adjust parameters quickly. In addition, preset modes help standardize protocols.
Ergonomic Handpiece Design
The handpieces are designed for comfort and precision. As a result, operator fatigue is reduced. Meanwhile, accurate energy delivery is maintained.
Reliable Clinical Performance
Built for high volume practices, the system offers durability and reliability. Consequently, clinics benefit from long term operational stability.
Clinical Applications
Laser Hair Removal
The GentleMax Pro is widely used for effective hair removal. Therefore, it delivers long term hair reduction across multiple skin types.
Vascular Treatments
Nd YAG technology supports treatment of vascular lesions. As a result, practitioners can address redness and visible vessels.
Pigmented Lesion Treatments
Alexandrite energy targets pigmented lesions. Consequently, skin tone appears more even.
Benefits for Clinics and Patients
Versatile Treatment Capabilities
Dual wavelength functionality allows treatment customization. Therefore, clinics can expand service offerings.
Enhanced Patient Comfort
Cooling technology reduces discomfort. As a result, patient satisfaction improves.
Consistent and Predictable Results
Stable energy output ensures reliable outcomes. Consequently, practitioners can confidently manage treatment plans.
Why Choose the 2020 Candela GentleMax Pro
The 2020 Candela GentleMax Pro offers a balanced combination of versatility safety and performance. Moreover, its dual wavelength design supports comprehensive aesthetic care. As a result, it remains a trusted solution for modern clinics.
Specifications – 2020 Candela GentleMax Pro
General Information
Manufacturer Candela Medical
Model GentleMax Pro
Release Year 2020
Device Type Dual wavelength aesthetic laser system
Clinical Use Professional medical aesthetic treatments
Laser Technology
Laser Type Solid state laser
Wavelengths 755 nm Alexandrite and 1064 nm Nd YAG
Emission Mode Pulsed
Pulse Duration Range Adjustable microsecond to millisecond range
Maximum Fluence High energy output optimized for clinical versatility
Treatment Applications
Laser Hair Removal
Vascular Lesion Treatment
Pigmented Lesion Treatment
Skin Revitalization
Pseudofolliculitis Barbae Treatment
Leg Veins Treatment
Spot Size Options
Spot Sizes Available 6 mm 8 mm 10 mm 12 mm 15 mm 18 mm 24 mm
Variable spot size selection for precise treatment control
Repetition Rate
Maximum Repetition Rate Up to 2 Hz
Optimized pulse delivery for controlled clinical workflows
Cooling System
Dynamic Cooling Device DCD
Cryogen Spray Cooling
Adjustable Spray Duration and Delay
Integrated epidermal protection system
Energy Delivery System
Advanced energy control algorithms
Uniform energy distribution across spot sizes
Consistent fluence delivery for repeatable clinical outcomes
Handpieces
Ergonomic lightweight handpieces
Quick change spot size capability
Integrated cooling compatibility
Durable fiber optic delivery system
User Interface
Color touchscreen display
Intuitive graphical user interface
Preset clinical parameters
Customizable treatment settings
Safety Features
Integrated skin cooling for epidermal protection
Real time system monitoring
Password protected access levels
Emergency stop button
FDA cleared laser platform
Power Requirements
Electrical Input 200 to 240 VAC
Frequency 50 to 60 Hz
Power Consumption Optimized for clinical environments
Dimensions and Weight
Console Design Floor standing unit
Compact clinical footprint
Optimized weight distribution for stability and mobility
Mobility
Medical grade caster wheels
Locking wheel system
Easy relocation within treatment rooms
Maintenance
Air cooled internal system
Minimal downtime requirements
Service access panels for routine maintenance
Regulatory and Compliance
FDA Cleared
CE Marked
IEC Medical Electrical Equipment Standards Compliance
Treatment Efficiency
High speed treatment capability
Reduced session time
Consistent energy output for reliable results
Patient Comfort
Integrated cryogen cooling
Minimized epidermal thermal impact
Improved treatment tolerance
Clinical Advantages
Dual wavelength versatility
Wide spot size range
Trusted clinical performance
Suitable for multiple skin types including darker skin tones
Target Users
Dermatology Clinics
Medical Aesthetic Clinics
Plastic Surgery Centers
Professional Laser Practices
Operating Environment
Operating Temperature Controlled clinical environment
Humidity Range Medical equipment standard tolerance
Includes:
– 6 -18mm handpiece DCD – with box
– 20 -24mm handpiece ACC – with box
– 2 goggles with case
– 2x unopened boxes of coated Sapphire windows + 12 in open box
– 13 slides windows
– All booklets and information from Candela
– distance gauges
– 6/8mm x 5
– 10mm x5
– 12mm x5
– 15mm x5
– 18mm x5
– 20mm x3
– 22mm x3
– 24mm x3









There are no reviews yet.